Measuring light for houseplants: a number for every spot
A phone light meter app or a lux meter, held level at leaf height, turns each spot into a reading in lux or foot-candles and a band on one stated scale, rechecked in winter.
- Start here: the essentials
- 1. What a light reading measures
- 2. Getting a reading with a phone or meter
- 3. The band scale: turning a reading into a band
- 4. Windows, the sun and the glass
- 5. Distance from the window
- 6. Seasons and the winter re-check
- 7. See it
- 8. Practice: a light survey of every spot
- 9. Your plants
- 10. Check your work
- 11. Knowledge check and scenario
Start here Essentials
At minimum this chapter asks you to take three readings at each spot that holds a plant, average them and read the band. Everything marked Go deeper is optional on a first pass.
- Install a light meter app or find your meter, and set it to lux or foot-candles (Getting a reading).
- Find which way each window faces with a compass app (Windows, the sun and the glass).
- Take three readings at each plant's spot on a clear day, sensor level and facing up at leaf height (Getting a reading).
- Average them and write the result, dated, on the light survey (What a light reading measures).
- Read the band from the scale (The band scale).
Minimum time: about 10 minutes per spot, spread over one clear day. Done when: every spot with a plant has a dated average reading and a band on the light survey.
1. What a light reading measures Understand
Plant tags describe light in words: "bright indirect", "low light", "part sun". The words are not wrong, but they are wide. University of Florida's Gardening Solutions page calls them generalizations, not scientific terms, and notes that a desk by a window may be ten times brighter than a space across the hall that looks only "slightly" darker (UF/IFAS, Light for Houseplants). Your eyes adapt to the room, so they are poor judges of how much light a spot gets. A number settles what the eye cannot. This chapter turns each spot where a plant sits into a number, and the number into a band that the rest of the manual uses.
Lux and foot-candles
Lux is the metric unit of illuminance: how much visible light falls on a surface, one lumen per square meter. A foot-candle (fc, also written ft-c) is the US unit, one lumen per square foot. Physical principle One foot-candle is 10.764 lux, because a square meter holds 10.764 square feet. Sources round the figure: Thimijan and Heins use 10.8, Iowa State uses 10.76, and UF says lux and foot-candles differ by "about a factor of 10". The rounding makes no difference to a houseplant band.
A light meter app or a lux meter reports one unit or the other, and most can switch. The light survey and the light calculator accept either. The conversion is one step:
| You have | You want | Do this | Example |
|---|---|---|---|
| Lux | Foot-candles | Divide by 10.764 | 1,500 lux ÷ 10.764 = 139 fc |
| Foot-candles | Lux | Multiply by 10.764 | 200 fc × 10.764 = 2,153 lux |
Worked through once: a phone reads 1,500 lux at a shelf. Divide by 10.764 and the shelf gets about 139 foot-candles. On the scale in The band scale, 139 fc sits inside the low band's grows-well range of 75 to 200 fc. A reading of 2,153 lux is 200 fc, the edge between low and medium. Round the result to the nearest whole foot-candle; the meter is not more precise than that.
Why a lux reading is a stand-in for plant light
Lux and foot-candles weigh light the way the human eye does. The eye is most sensitive to green and yellow and less sensitive to deep red and blue. Plants work the other way round. Physical principle They use photons across roughly 400 to 700 nanometers, the band called photosynthetically active radiation (PAR), and red and blue photons count as much as green ones (Thimijan and Heins, HortScience, 1983). Runkle and Bugbee, two horticultural lighting researchers, write that photometric units are biased toward people for exactly this reason.
The unit that counts plant light directly is PPFD, photosynthetic photon flux density: the number of PAR photons landing on a square meter each second, in micromoles per square meter per second (µmol m-2 s-1). Measuring it takes a quantum sensor, which costs far more than a phone. Daily light integral, DLI, is PPFD added up over a whole day, in moles per square meter per day. Runkle defines it as a figure built from a sensor logged often, every minute for example, across the day.
For daylight, lux is a fair stand-in, because sunlight's mix of colors is steady. Physical principle Apogee Instruments, a sensor maker, gives 54 lux per µmol m-2 s-1 for sunlight, the same figure Thimijan and Heins give for sun and sky (Apogee, Conversion: PPFD to Lux). The extension services' light categories were written in foot-candles, and the plant reference uses those categories, so this manual measures in lux or foot-candles and keeps PPFD and DLI for Grow lights, where a lamp's color makes lux misleading.
Why lux undercounts some grow lights. The ratio of lux to PPFD changes with the light source. Thimijan and Heins's table gives 54 lux per µmol for daylight, 74 for cool-white fluorescent tubes, 82 for high-pressure sodium and 33 for one plant-growth fluorescent. A red and blue grow light looks dim to the eye, and a lux meter reads it low, while it delivers a good deal of plant light. Runkle and Bugbee call foot-candles and lux especially unsuitable under LEDs. Under daylight through a window, the 54 figure holds; under a lamp, it does not. Grow lights shows how to estimate PPFD from a lux reading by the lamp's own factor.
Why one reading is not a daily total. Thimijan and Heins state that one sunlight reading does not give a 24-hour average, and Runkle wrote in 2007 that no instantaneous unit converts to DLI. A daylight DLI worked out from one phone reading is an estimate at best. The light calculator labels it that way.
A worked chain, for scale. 100 fc × 10.764 = 1,076 lux. Divided by 54 for daylight, that is about 20 µmol m-2 s-1. If that level held for 12 hours, Iowa State's formula (PPFD × hours × 0.0036) gives about 0.86 mol m-2 per day. Clemson's factsheet says about 100 fc for 12 hours a day maintains plant quality for a year, so this small number is a real working level for a houseplant, far below anything outdoors.
2. Getting a reading with a phone or meter
Two instruments will do: a light meter app on a phone, or an inexpensive handheld lux meter. Penn State's Master Gardener article on low-light plants describes the same habit with a cheap meter that reads both foot-candles and lux (Penn State Extension, Low Light Houseplants).
What a phone can and cannot tell you
A phone's light sensor exists to set screen brightness. In a laboratory test of 22 lux meters and 3 phones under 10 light sources, Tabaka and Wtorkiewicz found that the phones, and 13 of the meters, failed the basic limit for spectral error, and that phone sensors lack the angle correction a proper meter has. They concluded phones should be treated as light-level indicators, not measuring devices (Tabaka and Wtorkiewicz, Energies, 2022). Gutierrez-Martinez and colleagues found phones usable where high precision is not needed, accurate only after each phone was calibrated on its own, even against an identical model.
For the job here, that is enough. Iowa State calls smartphone apps adequate for the typical home gardener (Iowa State, Supplemental Light), and UF says apps are approximations that are good for detecting a change. Tennessee's extension guide calls foot-candle meters and phone apps low-cost and a good tool for assessing indoor conditions. Convention The default this manual uses: a phone is good for comparing spots in your own home with the same phone, and for placing a spot in a band that is two or three times wide. It is not good for deciding between two readings a few percent apart, or for comparing your number with a friend's phone.
Choosing an app. We do not name apps. Look for one that shows lux or foot-candles as a number (not only "low, medium, high"), can hold or average a reading, and says which sensor it uses. Iowa State advises setting the app or meter for the light source type where it offers one; for a window, that is daylight or sun. Arizona's extension guide calls meters that read only Low, Medium and High "ballpark figures".
How to hold it
The sensor on most phones sits on the front, near the camera at the top edge. A handheld meter has a white dome or disc. Either way:
- Put the sensor where the leaves are. Iowa State says to measure at foliage level; Runkle says at or near crop height, away from walls and shading objects. For a plant on a desk, that is the height of its top leaves, not the desk surface.
- Hold it level and facing up. Runkle says the sensor should be level. A phone held flat on your palm, screen up, with the front sensor clear, is level enough; for a meter, the dome faces the ceiling. Test it Tilt the phone toward the window and watch the number climb: that difference is why the angle matters.
- Keep your shadow off it. Stand to the side away from the window and hold the phone at arm's length. A hand or head between the sensor and the window lowers the reading.
- Keep the sensor clean. Runkle notes that dirt and mineral deposits make a sensor read low. Wipe a phone's top edge before a survey.
- Let the number settle, then write it down with the time.
Three readings, averaged
Light at a window changes through the day as the sun moves. One reading is one moment. Preference We take three readings at each spot on a clear day: mid-morning, around midday and mid-afternoon, and average them. This is our routine, not a published standard; it keeps a spot that gets a burst of morning sun from reading as brighter than it is all day, and a west spot read at 10 a.m. from reading darker than it is. UF's own table is stated for readings at mid-day. On a day with broken cloud, readings jump as clouds pass; wait for the sun to be steady, or take the three readings on another day.
The average is the three readings added and divided by three. A desk that reads 900, 1,800 and 1,200 lux averages 1,300 lux, about 121 fc. Write the three and the average on the light survey, with the date and the unit; the survey works out the average and the band for you.
Cosine response. Light that strikes a flat sensor at a low angle covers more area and counts for less. A good meter is built to weight light by the cosine of its angle, so that light from the side counts by the right amount. Apogee's research quantum sensor specifies its directional (cosine) response within 5 percent at 75 degrees from straight up, behind a diffuser (Apogee SQ-500 specification). Tabaka and Wtorkiewicz found phones have no such correction, and Gutierrez-Martinez and colleagues found a phone's internal sensor read mainly direct light while an external meter also caught indirect light. In practice, this is the reason to hold the phone the same way every time.
People's light, with the same habit. Learn Interior Lighting uses phone meters to survey rooms for people, with targets in lux for reading and tasks: Learn Interior Lighting, phone light meters. The holding rules are the same.
3. The band scale: turning a reading into a band
The extension services do not agree on what "low", "medium" and "high" light mean in numbers. Their boundaries differ by up to ten times. Four of them, Clemson, Tennessee, Georgia and Arkansas, agree on one scale for where a plant grows well, and Clemson, Tennessee and Georgia give the same minimums. Convention This manual uses that scale everywhere: in every chapter, in the plant reference, in the light survey and in the light calculator.
| Band | Grows well (foot-candles) | Grows well (lux, about) | Minimum to survive (foot-candles) |
|---|---|---|---|
| Low | 75 to 200 | 800 to 2,150 | 25 to 75 |
| Medium | 200 to 500 | 2,150 to 5,400 | 75 to 150 |
| High | 500 to 1,000 | 5,400 to 10,750 | 150 to 1,000 |
| Direct sun | Over 1,000, with hours of direct sun | Over 10,750 | Not given |
Sources: Clemson HGIC 1450 (its preferred column), Tennessee W 1128-A, Georgia B1318 (its plant categories) and Arkansas Master Gardener slides. Lux is foot-candles × 10.764, rounded. Tennessee and Georgia add about four hours of direct sun for the top band.
How to read the table
Find the band whose grows-well range holds your average. An average of 121 fc is in the low band. An average of 340 fc is medium. An average of 1,400 fc with a few hours of sun on the leaves is direct sun.
Two cases need a second look:
- Below 75 fc. The spot is under the low band's grows-well range. Between 25 and 75 fc it is still inside the low band's survival minimum; below 25 fc it is under every minimum on the scale. Write it on the survey as "below low" with the number, rather than rounding it up to low. Tennessee's guide shows a winter reading of 21 fc in an east-facing room and calls it quite low.
- On a boundary. A spot that averages 190 to 210 fc sits at the edge of low and medium. Note both bands. Readings from a phone are not precise enough to split it, and the next season may push it either way.
The arithmetic of the scale has one quirk to know about. The minimums overlap the band below: the medium band's minimum, 75 to 150 fc, sits inside the low band's grows-well range. That is how the sources wrote it. A plant listed as medium can live in a spot that reads as good low light, growing more slowly than it would at 300 fc. Matching plants to light uses both columns to decide what to do with a plant in that position.
A reading is one moment, in one season, through one phone. A band says where a spot sits on a stated scale; it does not say whether a particular plant will grow well there. The plant reference gives each plant's band from its sources, and the plant itself, over the following months, settles the rest: new leaves of normal size and color, or long gaps between small pale ones. Reading symptoms covers those signs.
Three extension scales, side by side. The manual's scale is one of three that recur. Missouri and Minnesota draw much wider bands, and UF and Maryland draw a lower one:
| Scale | Low (fc) | Medium (fc) | High (fc) | Direct (fc) |
|---|---|---|---|---|
| This manual's: Clemson, Tennessee, Georgia, Arkansas (grows well) | 75 to 200 | 200 to 500 | 500 to 1,000 | Over 1,000 |
| Missouri G6515 and Minnesota Extension | 50 to 250 | 250 to 1,000 | Over 1,000 | Not separate |
| UF Gardening Solutions (mid-day) and Maryland Extension | 25 to 100 | 100 to 500 | 500 to 1,000 | Over 1,000 |
Missouri says its categories generally indicate the minimum light required, with growth best at the high end. Others give single points or narrower bands: Illinois 75, 150, 300 and 1,500 fc; Arizona low 25 to 75, medium 75 to 150, high 150 to 1,000. Penn State's Master Gardener article says the definitions vary and that 100 fc is a common baseline for low light. Georgia's bulletin itself carries two scales, one for areas of a home and one for plant labels, and Clemson's plant tables are headed with different figures from its own category list.
Why the manual chose the four-source scale: four services agree on it, and it is the scale most plant profiles in the reference were written against. The cost is that a spot reading 220 fc is medium here and low on Missouri's scale; a plant tag from a grower who used another scale may disagree with our band by one step. Minnesota's page also gives micromole figures beside its foot-candles that do not match them under any published conversion, so we do not use those numbers.
4. Windows, the sun and the glass
Which way a window faces decides when the sun reaches it and how strong the light is. Test it Stand with your back to the glass and your phone flat, and read the heading on a compass app: the window faces the opposite way, the direction you would look out. A window you look out of toward the east is an east window. Write it on the light survey for each spot.
What each direction gets
Nebraska Extension puts it in proportions: if a south window is 100 percent, east and west windows get about 60 percent and north about 20 percent (Nebraska Extension, Let There Be Light). UC Cooperative Extension in Stanislaus County gives the same shares. These figures assume the Northern Hemisphere and an unshaded window.
| Window faces | Sun on it | What sources say |
|---|---|---|
| South | Most of the day, highest totals | Brightest and longest (Missouri); may sunburn plants from late spring to early fall (Missouri); a south window under wide eaves gets about as much as a north window (Georgia) |
| East | Morning | Morning sun, cooler rooms (Tennessee); Georgia records 5,000 to 8,000 fc in direct morning sun at an east window |
| West | Afternoon | Afternoon sun, warmer rooms (Tennessee); Georgia treats south and west as interchangeable for most plants |
| North | Little or none | Lowest light (Tennessee); UF says a north window may not reach even 400 fc; Georgia records a north windowsill as low as 200 fc on a clear winter day |
A corner window, a northeast or southwest one, behaves between its two neighbors. The point of the table is to know when to measure: an east window read at 3 p.m. reads its weakest, and a west window read at 9 a.m. reads its weakest. The three-reading routine catches both.
What else stands between the sky and the leaf
Maryland Extension lists curtains, insect screening, weather, season, shade, and the cleanliness and type of the window as things that change the light, and notes that light-colored walls and floors raise it (Maryland Extension, Lighting for Indoor Plants). Arizona adds roof overhangs, awnings, nearby buildings and trees. Penn State's author found thick translucent glass and tall buildings cut the light at a south window.
None of the sources we found give measured figures for how much a sheer curtain, a blind or a screen cuts. Test it Take the reading with the curtain as it usually hangs. If you want to know what a sheer costs your plant, take one reading with it closed and one with it open, a minute apart, and compare. Learn Window Treatments explains what sheers, light-filtering fabrics and blinds do to daylight: Learn Window Treatments, the four opacity words. Wash dusty glass before a survey; the reading should describe the window as it usually is, so keep it clean afterward too.
Glass. The only measured figures we found are for glass itself, from the Whole Building Design Guide, calculated with Lawrence Berkeley National Laboratory's window software (WBDG, Windows and Glazing). Visible transmittance, the share of daylight that passes: single clear pane 89 percent; double clear 79; triple clear 74; low-e double panes 70 to 75; double bronze reflective 21. A reading taken indoors already includes the glass, so these figures matter only when you compare an indoor reading with an outdoor one, or when a tinted window reads much lower than its size suggests.
The Southern Hemisphere. Every source in this chapter writes for the Northern Hemisphere. South of the equator the sun crosses the northern part of the sky, so a north window there plays the part a south window plays in the tables above, and a south window gets the least direct sun. No university or agency source we found states this for houseplants; it is the geometry of the sun's path, and our statement. If your setup says Southern, read "north" for "south" in this chapter's direction table. East and west keep their morning and afternoon roles.
5. Distance from the window
Light falls off quickly as you move back from a window. Nebraska Extension says moving a plant slightly farther from a window cuts the light very quickly, and Missouri says even low-light plants usually lack enough light more than 10 feet from an average window. The extension services describe the drop as distance bands rather than measured curves:
| Source | Distance guidance |
|---|---|
| Illinois Extension | Low (75 fc): a few feet from a north window, 3 to 10 ft from east or west, 15 to 20 ft from south. Medium (150 fc): directly in front of north, a few feet from east or west, 3 to 10 ft from south. High (300 fc): directly in front of east or west, up to 5 ft from south |
| Arizona AZ1025 | High: within 4 ft of large south, east or west windows. Medium: 4 to 8 ft from south and east windows. Low: more than 8 ft from windows; north exposures often low even close to the glass |
| Missouri G6515 | Even low-light plants usually lack light more than 10 ft from an average window |
These bands are a starting guess, and each was written for its own scale. Test it Your room settles it. Take readings at 1, 3, 6 and 10 feet straight back from the middle of a window, at the same height, within a few minutes of each other on a clear day. The four numbers are your room's own fall-off. The light survey has an optional fall-off sheet for them, seeded with those four distances (or 30, 90, 180 and 300 cm).
What the fall-off tells you: how far back a plant can sit and stay in its band, and whether a move of two feet toward the glass is worth making. No authoritative source we found gives a figure for how fast light drops with distance from a window, so we give none; the figures that circulate online ("half the light at 6 feet") come from forums and retailers. Your own four readings are better evidence than any of them for your room.
Distance also changes the angle. Close to a window, a plant sees a large patch of sky; well back, it sees a small one, and it leans toward it. Turning the pot regularly evens out the lean; Matching plants to light covers that and moving a plant to a brighter spot.
6. Seasons and the winter re-check
A survey taken in June describes June. In winter the days are shorter and the sun sits lower in the sky. Arizona's guide says winter brings shorter days and fewer hours of less intense sun, while a plant close to an unshaded south window may get more direct sun in winter because of the low angle. Georgia and Tennessee both say sunlight reaches farther into a room in winter, and Tennessee advises measuring across the room and across the seasons. Convention The overall change for most spots is a shorter, weaker day; the deeper winter sun patch is the exception at south windows.
Nebraska Extension gives the practical consequence: a plant that does fine in an east window in summer may need a south window in winter. A spot near the edge of a band in summer may fall below it in December.
The winter re-check
Preference Re-take the three readings at every spot in midwinter, in December or January in the Northern Hemisphere, and write them on the light survey as a new dated row. Compare them with the summer row. A spot that stays in its band needs nothing. A spot that drops a band is where a plant may need a winter move or extra light, and where it will dry more slowly between waterings. Humidity, temperature and the seasons covers the rest of winter care.
A midday reading in winter also misleads in another way: it says nothing about how many hours the light lasts. Clemson's figure of about 100 fc for 12 hours a day to maintain a plant links level and hours. A spot that reads the same at noon in December as in June still gets fewer hours of it. Grow lights shows how to account for hours with the daily light integral, as an estimate.
Write the date on every reading. A reading without a date is hard to compare with anything. The light survey keeps one row per spot per survey, so the summer and winter rows sit together.
7. See it See it
Dee's studio. Dee (fictional) rents a studio apartment with one window over her desk. She has two plants, both gifts: a pothos in a 6 in plastic nursery pot on the desk, 2 ft from the glass, and a snake plant in a 6 in nursery pot set in a holeless ceramic cachepot on the floor, 8 ft from the window. She has a phone light meter app and uses US units.
Known: the window faces east; she checked with a compass app, standing with her back to the glass. The two spots are 2 ft and 8 ft back. Assumed: that her phone reads within a useful range for comparing the two spots; she has no meter to check it against, so the assumption is hers and she treats both readings as approximate. Open: whether the snake plant's floor spot stays above the low band's minimum in December. Only readings taken in December settle that.
On a clear Saturday in October she takes three readings at each spot: mid-morning, around noon and mid-afternoon, phone flat on her palm at leaf height, standing to the side so her shadow falls away from the window.
| Spot | Morning (lux) | Midday (lux) | Afternoon (lux) | Average | Band |
|---|---|---|---|---|---|
| Desk, 2 ft (pothos) | 4,300 | 2,400 | 1,500 | about 2,730 lux = about 254 fc | Medium |
| Floor, 8 ft (snake plant) | 1,100 | 800 | 600 | about 833 lux = about 77 fc | Low, at its bottom edge |
The arithmetic, once: the desk's three readings add to 8,200 lux; divided by 3 that is about 2,733 lux, and 2,733 ÷ 10.764 is about 254 fc. The floor's add to 2,500 lux, about 833 lux on average, and 833 ÷ 10.764 is about 77 fc. The desk falls through the day, as an east window should once the morning sun moves off it; the floor moves much less.
The desk is in the medium band, above the low band the plant reference gives for pothos, which the pothos can use. The floor spot sits just above 75 fc, the bottom of the low band's grows-well range. That is in the band, but only by 2 fc, and a phone is not precise enough to separate 77 from 73. So she dates both rows and writes "re-check in December" on the floor row: if winter pulls that spot under 75 fc, the snake plant is under the low band's grows-well range, still inside its 25 to 75 fc minimum unless it falls further. The December readings settle it.
What she does not conclude: that either spot is "enough" for either plant. The band and the plant reference say where each plant stands on the scale. The plants, over the next months, say the rest.
- Clemson HGIC 1450: the light categories in foot-candles, with plants listed in each and the 12-hour maintenance figure.
- Tennessee Extension, Selecting Indoor Plants: the same scale as a table, a winter reading in an east room, and the signs of low light.
- UF/IFAS, Light for Houseplants: why the eye misjudges light, and what to expect from phone apps.
- Nebraska Extension, Let There Be Light: window directions in proportions and the seasonal move.
8. Practice: a light survey of every spot Practice
Minimum: three readings at one plant's spot on one clear day, averaged, dated and placed in a band on the light survey. Time: about 10 minutes per spot, at three times of day. Materials: a phone with a light meter app or a lux meter, a compass app, a tape measure, and the light survey (or paper).
- List the spots. Every place a plant sits now, and any place you are thinking of putting one. Give each a short name ("desk", "floor by bookcase").
- Record each spot's window. Its direction from the compass app, its distance from the glass, and any curtain, blind, screen or outside shade.
- Pick a clear day and plan three rounds: mid-morning, around midday and mid-afternoon.
- Take a reading at each spot in each round, sensor level and facing up at leaf height, your shadow out of the way. Write each number with the time.
- Average the three for each spot, or let the light survey do it, and read the band from the band scale.
- Write the plants that sit at each spot in the survey's "plants here" column.
- Put the winter re-check on your calendar for a clear day in December or January.
- Measure your room's fall-off. At one window, take readings at 1, 3, 6 and 10 ft straight back, at one height, within five minutes. Enter them on the survey's fall-off sheet. Note where the readings cross 200 fc and 75 fc.
- Measure what the curtain costs. At one spot, read with the sheer or blind as it usually is, then open, a minute apart. Write both.
- Check your phone against itself. Take five readings in a row at one spot without moving. The spread between them is the least difference you should treat as real.
9. Your plants Your plants
10. Check your work Check your work
Criteria
- Does every spot that holds a plant have three readings, an average, a unit and a date?
- Were the readings taken at leaf height, level and facing up, with no shadow on the sensor?
- Does each spot show its window direction and distance from the glass?
- Is each average placed in a band on the manual's scale, with "below low" or "edge of two bands" written where it applies?
- Is a winter re-check dated?
Worked example
Dee's survey has two rows, desk and floor, each with an east window, a distance, three readings, an average and a band, dated on the same clear October day: desk about 254 fc (medium), floor about 77 fc (low). Both meet the criteria. Her floor row carries a note: "re-check in December; 2 fc above the low band's floor". The note is the right one, because the floor reading is both the closest to a boundary and the one most likely to fall in winter. She left out a fall-off sheet, which is optional; her two rows already show the drop from about 2,730 lux at 2 ft to about 833 lux at 8 ft, roughly a third, at one window.
Common mistakes
- Reading at the desk surface, not the leaves. The top of a tall plant and the soil line can differ by a band near a window. Measure where the leaves are.
- Tilting the phone toward the window. The number goes up, and the spot reads brighter than it is. Hold it flat.
- One reading at noon. East and west windows read very differently at different hours. Take three.
- Mixing units. A reading in lux entered as foot-candles is ten times too high. Write the unit beside every number.
- Treating the band as a verdict. The band places the spot on the scale. The plant settles whether it does well there.
What is still unresolved
- Which plants suit each band, and what to do when a plant sits below its band: Matching plants to light and the plant reference.
- How much light a lamp adds, and the daily total over a short winter day: Grow lights and the light calculator.
- Whether a plant is actually short of light: its new growth, read as in Reading symptoms.
- How accurate your own phone is: only a calibrated meter, or a borrowed one, can check it.