Light, feeding and pot size calculators
Three calculators: a light reading turned into foot-candles, lux, a band on our scale and an estimated daily light, a fertilizer label's rate turned into the amount for your watering can, and the next pot size with the water it takes to leach.
Each calculator lists what its figures rest on at the foot of the page. They do arithmetic on numbers you bring: a reading from your light survey, the rate on a fertilizer label, the pot in front of you. None of them knows your plant; the plant and its log settle what the numbers mean.
Light reading to band and daily light
Enter one reading or the average of three from the same spot. The calculator converts it between lux and foot-candles (1 fc = 10.764 lux), places it on the scale in Measuring light, and estimates the light plants use (PPFD) from the light source's factor. With hours of light a day it estimates the daily light integral (DLI); with a target DLI it works out the hours. Estimating PPFD from a lux reading explains why the PPFD is a range for LEDs and why the daily figure is an estimate for daylight.
Fertilizer dilution for your watering can
Copy the label's amount and the volume of water it goes into, choose a strength, and enter what your can holds. The calculator scales the label's rate to the can. Full strength is the label's rate; half or quarter strength is your choice, where a source or your own experience says to feed lighter (Mixing a dilution). Choose "other" and type a fraction (0.33 for a third) for any other strength.
Next pot size
Measure the current pot's inside diameter across the rim and say why you are repotting. The calculator gives the next size by the 1 to 2 inch convention most of our sources share (Repotting), the root-pruning rule for keeping a plant in its pot, and roughly how much water leaches a pot of that size.
These are conversions and conventions. A band says what range a reading falls in, not whether your plant will grow there; a PPFD from lux is an estimate within the factor's uncertainty; the fertilizer label governs its own rate; and the roots you see when you tip a plant out decide its pot. Electrical questions about a grow light go to its maker or an electrician.
Assumptions behind the numbers
- Light, units: 1 foot-candle = 10.764 lux (Thimijan and Heins 1983, HortScience).
- Light, bands: low 75 to 200 fc, medium 200 to 500, high 500 to 1,000, direct over 1,000 with hours of sun; survival minimums 25 to 75, 75 to 150 and 150 to 1,000 (Clemson HGIC 1450, Tennessee W1128-A, Georgia B1318, Arkansas Master Gardener). Below 25 fc the band is shown as below low.
- Light, PPFD estimate: lux divided by 54 for sunlight and by 74 for cool-white fluorescent (Apogee Instruments, after Thimijan and Heins); white LEDs about 55 to 70 lux per µmol/m²/s by color temperature, from one lighting software maker's table (AGi32), shown as a range. "Not sure" shows the range 54 to 74. A lux reading under a red-and-blue grow light misleads; use the maker's PPFD chart there.
- Light, daily light integral: DLI (mol/m²/day) = PPFD × hours × 0.0036 (Iowa State Extension). A daylight DLI from one reading is an estimate at best, because daylight changes through the day (Thimijan and Heins; Runkle, GPN 2007).
- Feeding: 1 US gallon = 3.785 liters, 1 quart = 0.946 liter, 1 tablespoon = 3 teaspoons, 1 teaspoon = 4.93 milliliters (NIST Handbook 44, Appendix C). Grams stay grams; we do not convert a dry product's weight to spoons, because density varies by product. The label's directions govern.
- Pot: the next pot 1 to 2 inches (2.5 to 5 cm) wider than the current one (Colorado State PlantTalk 1316, Purdue HO-39, RHS). Leaching water scaled from WSU's figure of about 10 cups for a 6 in pot leached with about 20 cups (twice the pot's volume, PNW Handbook chapter 14), by the cube of the diameter; an estimate that assumes a standard pot shape.