Grow lights
Light

Grow lights for houseplants: choosing, placing and timing one

What PPFD, PPF, efficacy and a color label say, a light's output at the leaf read from the maker's chart or estimated from a lux reading, hours set on a timer, and heat, glare and cords handled.

Start here Essentials

At minimum this chapter asks you to put a number on one grow light at one plant: how much light reaches the leaves, for how many hours, and what that adds up to in a day. Everything marked Go deeper is optional on a first pass.

  1. Measure the spot with the grow light off, so you know what the plant already gets (Estimating PPFD from a lux reading).
  2. Find the light's PPFD at the distance you can hang it on the maker's chart, or estimate it from a lux reading with the light calculator (What a grow light's label says).
  3. Set a timer for the hours the calculator gives, inside the range the extension services use (Daily light and hours on a timer).
  4. Look at the new leaves again after about three weeks and write down what changed (Distance, spread and where the light goes).

Minimum time: about 30 minutes, plus a look in three weeks. Done when: the light, its distance from the leaves, its hours and the estimated daily light integral are written on the plant's card in Plant cards and logs.

1. What a grow light's label says Understand

A grow light is sold on words that sound precise and often are not. Four numbers can tell you something real about it, and two common words tell you very little. Before the numbers, the difference that matters most.

A lux or foot-candle reading (1 foot-candle is 10.764 lux; Thimijan and Heins round it to 10.8) measures light as the human eye weighs it, with green and yellow counted most. Plants weigh light differently. They use photons between 400 and 700 nanometers, a band called PAR (photosynthetically active radiation). Runkle and Bugbee, writing in Greenhouse Product News in 2013, explain that counting the photons in that band equally, whatever their color, best predicts photosynthesis, and that this is why red and blue LEDs can look dim to a person and still deliver a lot of light to a plant, and they call foot-candles and lux "especially unsuitable" for LEDs. Physical principle A lux meter, and the phone app that stands in for one, tells you how bright a light looks to you. It does not tell you directly how much a plant can use. Measuring light covers the units in full; this chapter uses them for one job, sizing a light.

The plant units, as Erik Runkle defined them in his 2025 Greenhouse Product News column and Iowa State Extension uses them:

Label termUnitWhat it measuresWhat it does not tell you
PPF (photosynthetic photon flux)µmol/sThe photons in the 400 to 700 nm band the whole fixture puts out each second. Runkle notes it is measured in an integrating sphere, not with a handheld sensor.How much of that light lands on your plant. A light can have a high PPF and spread it over a whole shelf.
PPFD (photosynthetic photon flux density)µmol/m²/sThe photons that reach one square meter of surface each second, at a stated distance. This is the number at the leaf.Anything unless the distance is stated with it. PPFD falls as the light moves away and toward the edges of its footprint.
Efficacy (photosynthetic photon efficacy, PPE)µmol/JPhotons out per joule of electricity in: PPF divided by watts.How bright the light is at your plant. It is a running-cost figure.
WattsWElectricity the light draws.Light output. Iowa State says watts measure energy use only.
LumenslmTotal output weighted for the human eye.Plant light. Iowa State's sources page says lumens describe what the eye sees, not PPF, though they beat watts as a rough guide for a white light.
Color temperaturekelvin (K)Whether a white light looks warm (around 2700 K) or cool (4000 K and up).Iowa State says kelvin indicates approximate color only, not the light's spectrum in detail.
"Full spectrum"noneA marketing description.Anything measurable; see below.

PPFD at a distance: the number to look for

A grow light worth sizing comes with a PPFD figure at one or more distances, often as a chart or a grid of numbers under the light's footprint. Iowa State's sources page notes that grow-light LEDs often list PPF. If the box gives PPF only, it tells you the light's total output and nothing about your plant's leaves. If it gives neither PPF nor PPFD, you are left with lumens and a lux reading, which the next section turns into an estimate. Product-specific The chart is the maker's measurement of its own light; read it for the distance you can actually hang the light, not the shortest distance on the chart.

Efficacy and the DesignLights Consortium list

Efficacy is the figure that sorts efficient lights from wasteful ones. In a January 2022 column, Runkle reported that the DesignLights Consortium's horticultural list then held more than 600 products ranging from 1.81 to 3.69 µmol/J. The DesignLights Consortium (DLC) is a nonprofit that keeps a Qualified Products List of horticultural fixtures. Since April 18, 2025, under its Horticultural Technical Requirements V4.0, a fixture needs at least 2.5 µmol/J to be listed. The list is written for commercial growers and utility rebate programs, so most lights sold for a shelf of houseplants will not appear on it. A light that is not on the list is not thereby a bad light; the list gives you a benchmark to compare a label against.

A worked check, with figures made up for the arithmetic: a light labeled 20 W and 40 µmol/s PPF has an efficacy of 40 / 20 = 2.0 µmol/J. That sits below the DLC's 2.5 floor and inside the 2022 list's range. It says the light turns electricity into plant light less efficiently than a listed fixture. It says nothing about whether it is bright enough at your plant; only the PPFD at your distance says that.

Runkle's 2022 column also gives the reason white lights score lower: red LEDs are about 30 percent more efficient than blue, blue about 20 to 25 percent more efficient than white, and the most efficient fixtures are 90 to 95 percent red. White LEDs trade some efficacy for light that shows a plant's true colors to the people looking at it. For a few houseplants in a living room, that trade is usually the one people make.

"Full spectrum" and color labels

"Full spectrum" has no standard meaning that we found. The one source on the term, a 2020 Greenhouse Grower article reporting a lighting maker's view, calls it a marketing term implying sunlight-like output, and notes that the commercial lighting industry had used it for lamps with a color rendering index over 90. Convention Treat it as a description of how the light looks, and read the PPFD and efficacy instead.

Labels sorting grow lights into "red", "blue" and "white" or "balanced" are more useful. The University of Minnesota Extension says white or balanced lights suit most plants, and Iowa State notes that red and blue grow LEDs look pink or purple. A pink light in a living room is a real cost to the people in it; a white light is easier to live with.

2. Estimating PPFD from a lux reading

When a light has no PPFD chart, or when you want to know what an ordinary lamp or a ceiling fixture already gives a plant, you can estimate PPFD from a lux reading. Iowa State says lux readings can be converted to PPFD with tables or calculators, and that a phone app should be set for the light source type. The conversion depends on the light source, because each source spreads its photons differently across the colors the eye weighs and the colors a plant uses.

The rule: PPFD ≈ lux ÷ factor, where the factor is the number of lux that one µmol/m²/s of that source produces. Physical principle The factors below come from computing both units from each source's measured spectrum.

Light sourceLux per µmol/m²/sSource of the figure
Daylight (sun and sky)54Thimijan and Heins (1983); Apogee Instruments
Cool-white fluorescent74Thimijan and Heins; Apogee
Warm-white fluorescent76Thimijan and Heins
Incandescent50Thimijan and Heins
Plant-growth fluorescent (two types)33 and 54Thimijan and Heins
White LED, 2700 Kabout 55AGi32 documentation (one software maker), from one LED family
White LED, 3000 Kabout 58AGi32, as above
White LED, 3500 to 5000 Kabout 68 to 70AGi32, as above
Red and blue grow LEDsno factor foundUse the maker's PPFD chart

The white LED figures need a label of their own. They come from the documentation for AGi32, a lighting design program made by Lighting Analysts, Inc., which lists PPFD per kilolux for one maker's white LEDs at five color temperatures (14.3 µmol/m²/s per 1,000 lux at 4000 K, for example, which is about 70 lux per µmol/m²/s). They are the only white LED factors we found in a source we could read, and they describe one family of LEDs, not every white LED. Product-specific We use them as a range, about 55 to 70, and the light calculator shows that range when you choose a white LED.

A worked estimate

A reading of 1,000 lux under a cool-white fluorescent tube: 1,000 ÷ 74 = about 13.5 µmol/m²/s. The same 1,000 lux in daylight: 1,000 ÷ 54 = about 18.5. The same 1,000 lux under the first plant-growth fluorescent in Thimijan and Heins's table: 1,000 ÷ 33 = about 30. Three lights that look equally bright to the eye give the plant amounts that differ by more than two to one. That spread is the whole reason lux misleads under a grow light.

If you do not know the source, the calculator's "not sure" option shows the range across the factors, and the honest answer is that range.

How good the estimate is

Thimijan and Heins put the conversion error for generic sources at under 10 percent, from lamp aging, operation and differences between makers. They also cite a study in which three light sensors under one source differed from each other by 22.5 percent, and quote an expected 10 to 25 percent error for measurements taken in less than ideal conditions. A phone adds its own error on top. Tabaka and Wtorkiewicz tested three phones and 22 lux meters in a laboratory in 2022: the phones, and 13 of the meters, failed the basic limit for spectral error, and the authors conclude that phone sensors are light-level indicators, not measuring devices. They also found that correction factors differ between fluorescent and LED sources of the same color temperature, so knowing the lamp type does not remove the phone's error.

Limits

A PPFD worked out from a lux reading is an estimate, inside the factor's uncertainty and the meter's. Treat a result as a range rather than a single figure, not as a measurement, and do not compare it to a figure measured with a quantum sensor as if the two were the same kind of number. The estimate is good for comparing spots and choosing hours. It does not settle whether a particular plant will grow at that spot: the plant's own new leaves over the following weeks settle that, recorded in the growth log. A quantum sensor, the instrument that measures PPFD directly, is what researchers use; Apogee's specification for one shows a cosine response within 5 percent at a steep angle, which no phone offers.

Go deeper

Who says what about the daylight factor. Apogee and Thimijan and Heins both give 54 lux per µmol/m²/s for sunlight; Thimijan and Heins give 52 for blue sky alone; AGi32's daylight figures work out to about 54 to 55. Apogee's page states the year of the Thimijan and Heins paper as 1982; the journal issue is December 1983. We use 54 throughout.

The reverse factors. Apogee also prints the multipliers that go the other way: lux × 0.0185 for sunlight and lux × 0.0135 for cool-white fluorescent. They are the same numbers as 1/54 and 1/74.

Why the factor changes with color. Runkle and Bugbee explain that lux weights green and yellow most, because the eye sees them best. A light rich in those colors therefore reads high in lux for the photons it delivers, and its factor is high. AGi32's table shows the pattern among white LEDs: about 55 at 2700 K and about 70 at 4000 K. Runkle and Bugbee's 2013 column recommends that growers stop using lux and foot-candles altogether; for a home reader with a phone, an estimate with its range stated is the workable middle.

3. Daily light and hours on a timer

PPFD is a rate: photons per second. A plant's day depends on the rate and on how long it lasts. The daily light integral (DLI) is the total: the moles of photons that land on a square meter in a day, written mol/m²/day. Iowa State gives the formula for a light that stays constant:

DLI = PPFD × hours × 0.0036

The 0.0036 is unit housekeeping: 3,600 seconds in an hour, divided by 1,000,000 µmol in a mole. Physical principle Because DLI is a count of photons, light from two sources adds: a plant that gets some window light and a grow light on top has the sum of the two.

Hours for a target

Turn the formula around and it gives the hours a light needs to run: hours = target DLI ÷ (PPFD × 0.0036). Suppose, for the arithmetic, a maker's chart gives 70 µmol/m²/s at the distance you can hang the light, and you aim for 3 mol/m²/day. 3 ÷ (70 × 0.0036) = 11.9 hours, so a 12-hour timer reaches it. At 100 µmol/m²/s the same target takes about 8.3 hours. The light calculator does this from your own figures when you fill in its target field.

Where does a target come from? Iowa State groups indoor plants by the DLI they need:

Iowa State categoryDLI, mol/m²/dayPlants Iowa State names
Low light3 to 6Foliage houseplants
Medium light6 to 10Foliage and flowering houseplants, cuttings, seedlings at the high end
High light12 to 16Flowering houseplants, succulents, seedlings at the low end, leafy herbs and vegetables
Very high light18 to 30Herbs, fruits, vegetables

These categories sit well above what this manual's foot-candle scale works out to over a day of daylight, and the two are not interchangeable. Why the two daily light scales do not line up sets them side by side. In practice: use Iowa State's figures as a target when you size a grow light that does most of a plant's lighting, and use the band from the light scale in Measuring light when you place a plant by a window. Do not take a window reading's DLI and judge it against Iowa State's table.

How many hours

Convention Iowa State Extension's default is 12 to 14 hours of light a day, no fewer than 10 and no more than 16, on a timer; for a fixture sold as a grow light it says to follow the package directions and gives 14 hours. The University of Minnesota gives 12 to 14 hours for foliage houseplants and 14 to 16 for flowering ones. Illinois, Maryland and Iowa State all set 16 hours as the top. A timer matters because the formula assumes the light runs the same hours every day; a light switched on when you remember is a DLI you cannot work out.

Your own exception: a plant whose flowering depends on the length of the night, such as a holiday cactus, needs its dark period kept dark. Iowa State says to avoid stray light during the dark period for flowering plants. Plants, one by one notes the plants where this applies.

Two limits on the arithmetic. First, the formula is exact only for a lamp that stays the same all day. Daylight does not: Thimijan and Heins say one sunlight reading does not give a 24-hour average, and Runkle, writing in 2007, says no instantaneous reading converts to DLI. A DLI worked out from one window reading is an estimate at best. Second, a DLI for a grow light is only as good as the PPFD you put in; from a lux estimate it inherits that estimate's range.

4. Distance, spread and where the light goes

Light from a fixture spreads as it travels, so the PPFD at the leaves falls as the light moves away. The University of Minnesota defines PPFD as the light reaching a surface and says it falls with distance. Physical principle PPFD is also highest under the center of the light and lower toward the edges of its footprint. Missouri Extension's table for fluorescent tubes shows both effects: under one fixture, 260 foot-candles at 1 ft below the lamps and 200 at 1 ft to the side; 500 at half a foot, 260 at 1 ft and 110 at 2 ft. Missouri also notes that the ends of a tube give less light than its middle.

The default: the maker's chart

Product-specific Hang the light at the distance its maker's PPFD chart gives for the light level you want, measured from the light to the top leaves, and put the plant under the center of the footprint. A rule of thumb from another light does not carry over, because two lights at the same distance can differ by several times in PPFD.

If the light has no chart, the extension services give starting distances: Iowa State, 12 to 24 inches for LEDs in most cases and 6 to 12 inches for fluorescent tubes; the University of Minnesota, 12 to 24 inches for foliage houseplants and 6 to 12 inches for flowering ones. Test it With no chart, a lux reading at the leaves turned into a PPFD estimate is the best you have; take it at the distance you choose and again at the edge of the plant.

An ordinary household LED as the light

A plant does not need a fixture sold as a grow light. Iowa State describes using an ordinary 4-foot plug-in LED shop light, labeled "daylight", with at least 3,000 lumens, 18 inches above the foliage for 14 hours, and says trial and error is acceptable because most indoor plants tolerate a wide range. The same reasoning covers a desk lamp or a ceiling fixture: read its lux at the leaves, choose the factor for its color temperature, and work out its PPFD and DLI as an estimate. Learn Interior Lighting's section on color temperature explains the kelvin figure on a household bulb's label.

Watching the plant

The leaves settle what the arithmetic cannot. New growth that is compact, at a normal leaf size and color, says the light is reaching the plant. Stretched stems with long gaps between leaves, small pale new leaves, and a plant leaning toward the light are the low-light signs the University of Tennessee, Georgia and Minnesota Extensions all list. Bleached or scorched patches on the leaves nearest the light are the too-much-light sign Minnesota and Maryland describe; raise the light or shorten the hours. The University of Georgia gives a new plant at least three to four weeks in a bright spot to adjust before its final place, and says every move brings another adjustment period. Look again after about three weeks before changing anything, and change one thing at a time. Reading symptoms has the full list of light symptoms and what else can look like them.

5. Heat, eyes, cords and water

Heat. Iowa State says LEDs run cooler than other sources and that reflectors can get hot; incandescent and high-intensity discharge lamps run hot. The extension services' distances above also keep leaves out of the heat near a lamp. Test it After the light has been on for an hour, hold the back of your hand at leaf height under it: if it feels warm there, the leaves feel it too, and the light goes higher.

Eyes. Grow lights are bright at close range. The international standard IEC 62471 sorts lamps into risk groups by how long a person could look into them before reaching the exposure limit. An LED maker's application note from ams OSRAM summarizes them: risk group 0 (exempt) has no photobiological hazard; risk group 1 (low risk) has none under normal behavior; risk group 2 (moderate risk) relies on the natural aversion to very bright light. The same note explains that the blue-light hazard depends on how bright the source is, not only on how blue it is, and that white LEDs fall within the blue-light band because of how they make white light. Product-specific If the maker states a risk group, it is on the label or in the instructions. Either way, do not look directly into a grow light. Preference We hang one so its bare face is above eye level from where people sit.

Cords, timers and water. A grow light sits where plants are watered and misted. Keep the light, its cord, its plug and its timer out of the path of water and away from drips off the pot and saucer, and follow the maker's instructions for mounting, heat, outlets and timers. This manual gives no electrical advice: wiring, a fixture mounted to a ceiling or wall, or an extension cord in permanent use is a question for the light's maker or an electrician. In an office or a rental, the building manager decides whether a plugged-in light is allowed.

Go deeper 6. Why the two daily light scales do not line up

This manual places plants on one foot-candle scale (the light scale in Measuring light), taken from Clemson, Tennessee, Georgia and Arkansas Extensions. Iowa State gives daily light integrals for the same kinds of plants. Converted, they disagree. Here is the conversion, ours, using daylight's factor and a 12-hour day of steady light at the band's level:

Manual's band (grows well)Foot-candlesPPFD in daylight, µmol/m²/sDLI over 12 hoursIowa State's category
Low75 to 200about 15 to 40about 0.6 to 1.7Low: 3 to 6
Medium200 to 500about 40 to 100about 1.7 to 4.3Medium: 6 to 10
High500 to 1,000about 100 to 200about 4.3 to 8.6High: 12 to 16

The arithmetic, for the low band's bottom: 75 fc × 10.764 = 807 lux; ÷ 54 = about 15 µmol/m²/s; × 12 × 0.0036 = about 0.65 mol/m²/day. Iowa State's low category starts at 3, about five times higher.

None of the sources explains the gap. Our reading of it, labeled as ours: the two scales answer different questions.

  • The foot-candle scale describes keeping a plant indoors. Its minimums are survival figures, and its grows-well ranges describe where foliage plants hold up in homes. Clemson says about 100 foot-candles for 12 hours a day maintains a plant's quality for a year (about 0.86 mol/m²/day by our conversion), and that a foliage plant needs at least 200 foot-candles for 12 hours (about 1.7) before it shows any benefit from fertilizer.
  • Iowa State's scale is written for growing plants under lights. Its page is about supplemental lighting, and its categories run on to seedlings, herbs and vegetables, which are grown for growth. Faust and Logan's 2018 research review gives a sense of where growth starts: two azalea cultivars broke even (their light compensation point) at 1.7 to 2.1 mol/m²/day, and post-production flowering quality needed 3.3. Azaleas are not foliage houseplants, so these figures show the order of magnitude, not a target.

The conversion itself does not explain the gap away. A steady 12 hours at the band's level is generous for a window, where light rises and falls through the day. Daylight's factor of 54 is lower than cool-white fluorescent's or a cool white LED's, so assuming electric light would lower the PPFD further. A phone reads with errors of its own, but not errors of five times. The gap is real, and we found no conversion that closes it.

What the manual does with it: a window spot is placed by its band on the foot-candle scale, and its DLI is shown only as an estimate, not judged against Iowa State. A grow light that does most of a plant's lighting can be sized to Iowa State's lower categories, and the plant's growth over the following weeks says whether that was more than it needed. The Minnesota Extension page also prints µmol figures beside its foot-candle bands; they do not match its own foot-candle figures under any conversion we found, so we do not use them.

Go deeper 7. Spectrum, fluorescent tubes and winter-only light

Spectrum and plant shape

Light color changes how a plant grows, not only how fast. Clemson says ordinary incandescent lamps make plants leggy, and Iowa State says incandescent light is heavy in red and low in blue, and that plants grown under high-pressure sodium alone can get leggy. Runkle and Bugbee note that far-red light, just past 700 nm, is barely visible but biologically active, and Runkle's 2025 column defines an extended PAR band of 400 to 750 nm that includes it. Florida's Gardening Solutions says plants grow better under broad-spectrum light, and that cool white works while warm white and daylight lights may. Iowa State suggests mixing warm and cool white for a wider spectrum. For houseplants kept for their leaves, a white light avoids most of the questions.

Fluorescent tubes

Fluorescent tubes were the standard plant light before LEDs, and many homes still have them. Iowa State gives 6 to 12 inches from the plants, prefers T5 tubes to T8 or T12, and says to replace tubes every one to two years because their output drops; its example is a 4-foot two-tube T5 high-output fixture 9 inches above the foliage for 14 hours. Arizona Extension gives two 40-watt tubes about 12 inches above plants. Cool-white fluorescent's factor (74 lux per µmol/m²/s) is the best-established of any source in the table, which makes a fluorescent tube the easiest light to estimate from a phone reading. Missouri's 2017 page says LED plant lights emit only red and blue light and are costly; Iowa State (2023) and Minnesota (2026) describe white LEDs as common and affordable, and Missouri is dated on this point.

Hours across the sources

The sources range from 12 to 18 hours. Clemson and Georgia give 16 hours of light and 8 of dark; Illinois 14 to 16, not more than 16; Arizona, Tennessee and Nebraska 12 to 16; Minnesota 12 to 14 for foliage and 16 to 18 for seedlings; Maryland no more than 16. Missouri gives 16 to 18 hours for plants with no outdoor light and 12 to 14 for plants that also get window light. We use Iowa State's 12 to 14 as the default because its pages are written about supplemental light for indoor plants, sit inside every other source's range, and state their bounds (10 and 16).

Supplementing a dim window in winter only

Some readers need a light only from late autumn to early spring, when days are short and a window spot drops a band (Measuring light covers the winter re-check). Missouri says plants with some window light need 12 to 14 hours from the lamp, run during daylight; Tennessee says supplemental lights run 12 to 16 hours can extend day length. Run the light during the day, so the window and the lamp add, and work out only the lamp's share as a DLI; the window's share stays an unknown you watch through the plant's growth. Faust and Logan's maps show how far outdoor light falls in winter: in January, Seattle gets 5 to 10 mol/m²/day outdoors, before any window glass.

8. See it See it

Fictional example

Priya's office desk. Priya (fictional) works at a desk about 20 ft from the nearest window, under ceiling LEDs that run 7 a.m. to 7 p.m. on weekdays and are off at weekends. She has chosen a ZZ plant and is thinking about a small clip-on LED grow light.

Known: her phone reads about 350 lux at the desk, which is about 33 foot-candles (350 ÷ 10.764 = 32.5); the lights run 12 hours a day, five days a week. Assumed: the ceiling LEDs are 4000 K, from the building's facilities sheet, which Priya has not checked against the fixtures; and that the phone's reading is within a useful range under these LEDs. Open: the estimated daily light at the desk, which the light calculator settles as an estimate; and whether the building allows a plugged-in grow light, which only facilities can settle.

The estimate. For a 4000 K white LED, AGi32's figure works out to about 70 lux per µmol/m²/s. 350 ÷ 70 = 5.0 µmol/m²/s. Over 12 hours: 5.0 × 12 × 0.0036 = 0.22 mol/m²/day. If the LEDs are warmer than the sheet says, the factor drops toward 55, which gives about 6.4 µmol/m²/s and 0.27. So under these assumptions the desk gets potentially about 0.2 to 0.3 mol/m²/day on weekdays from the ceiling, and nothing from it at weekends. Spread over the week, that is about 0.15 to 0.2 a day.

What the estimate settles, and what it does not. On the manual's foot-candle scale, 33 fc is below the low band's grows-well range (75 to 200) and inside the range Tennessee and Georgia give as the minimum to survive (25 to 75). Clemson's maintenance figure is about 100 fc for 12 hours a day; the desk has about a third of that, five days in seven. The estimate does not settle whether a ZZ plant will hold up there. It rests on a phone reading with its own error, a color temperature nobody has checked, and an unknown share of daylight from the far window at weekends. Plants, one by one gives the ZZ plant's band; the plant's new growth over the next months settles the rest.

The grow light question. If facilities allow it, the light's PPFD chart at the distance the clip can reach goes into the light calculator with the hours she would set, and its DLI adds to the ceiling's. If the clip-on light has no chart, she can read its lux at the leaves, choose its color temperature, and get a second estimate. Her plant card then records the light, its distance, its hours and the combined estimate, marked as an estimate.

9. Practice Practice

Minimum: one plant, one light (a grow light, a desk lamp or the ceiling fixture it already sits under), one estimate written on the plant's card. Time: about 30 minutes, plus a look in three weeks. Materials: a phone light meter app or a lux meter, a tape measure, the light's box or instructions if you have them, and a plug-in timer if the light has none.

  1. Read the spot with the light off. Hold the phone or meter level at the top leaves, sensor facing up, with no shadow from you, and write down the reading. In daylight, take it as Measuring light describes. This is what the plant gets without the light.
  2. Find the light's facts. On the box, the instructions or the maker's page, look for PPFD at a distance, PPF, watts, color temperature and any risk group. Write down what is there and what is missing.
  3. Get a PPFD at the leaves. With a chart: read the PPFD at the distance from the light to the top leaves. Without one: turn the light on, read the lux at the leaves, subtract the light-off reading if it is daylight you are separating out, and put the lamp's share into the light calculator with the light's source type.
  4. Choose the hours. Enter the hours you can run the light, or a target DLI, in the calculator. Set the timer inside 12 to 14 hours unless the maker's directions say otherwise.
  5. Write it down. On the plant's card in Plant cards and logs: the light, the distance, the hours, the estimated PPFD and DLI, and the word "estimate" if it came from lux.
  6. Look again in about three weeks. Note new leaf size and color and the gaps between leaves in the growth log.
Go deeper

Map the footprint. With the light on and the timer set, take lux readings at leaf height under the center of the light and at 6 and 12 inches out to each side. Convert each with the same factor. The drop toward the edges tells you how much room the light really covers, and where the plants that need the most light belong.

Check the distance against the chart. If the light has a PPFD chart, read lux at two of the chart's distances and convert. The ratio between your two estimates should be close to the ratio between the chart's two figures, even if neither estimate matches the chart exactly; a big difference suggests the phone is struggling with this light's spectrum.

10. Your plants Your plants

11. Check your work Check your work

Criteria

  • Does your plant's card name the light, its distance from the top leaves, its hours and an estimated DLI?
  • Does the PPFD come from the maker's chart at your distance, or is it marked as an estimate from lux with the factor named?
  • Is the light on a timer, inside the hours the extension services give, with the dark period kept dark for a plant that needs it?
  • Did you compare a grow light's DLI to Iowa State's categories, and a window spot to the foot-candle band, without mixing them?
  • Are the light, its cord and its timer out of the way of water?

Worked example

Priya's card (fictional) reads: "ZZ plant, desk. Ceiling LEDs, assumed 4000 K. 12 h weekdays, off weekends. 350 lux, about 33 fc. Estimate 5 µmol/m²/s, about 0.2 to 0.3 mol/m²/day weekdays. Grow light: waiting for facilities." It meets the first two criteria and marks its assumption. The third does not apply yet; the ceiling lights are on the building's own timer.

Common mistakes

  • Reading lux under a red and blue grow light and treating it as a measure. No factor exists for those lights in the sources we found; use the maker's chart.
  • Reading the chart at the wrong distance. The headline figure is usually the closest distance. Measure from the light to the top leaves where it actually hangs.
  • Judging a window's DLI against Iowa State's table. A window reading gives a band on the foot-candle scale; its DLI is an estimate that sits well below Iowa State's categories for reasons the two-scale comparison explains.
  • Moving the light, the hours and the plant all at once. Change one thing and give it about three weeks, or the new leaves cannot tell you which change mattered.
  • Leaving the cord across the saucer. Route it away from where water lands before the first watering under the light.

What is still unresolved

Whether a particular plant grows well under your light is settled by the plant over weeks, recorded in the growth log, not by the number. Which plants need how much light is in Matching plants to light and Plants, one by one. Wiring, fixed fixtures and outlets are for the light's maker or an electrician, and in a workplace or rental, for whoever manages the building.

12. Knowledge check and scenario

Two grow lights are labeled with the same PPF. Why can they give your plant different amounts of light?
PPF is the fixture's total output. What reaches the leaf is PPFD, which depends on how far away the light hangs and how widely it spreads its output. A light that spreads the same PPF over a wide shelf gives less PPFD at any one plant than one that concentrates it.
A phone reads 2,000 lux under a cool-white fluorescent tube. Roughly what PPFD is that, and how sure is the number?
2,000 ÷ 74 = about 27 µmol/m²/s. It is an estimate: the conversion carries up to about 10 percent error for generic sources, measurements in ordinary conditions 10 to 25 percent, and a phone adds its own spectral and angle error. Call it "about 27", as a range.
A light's chart gives 50 µmol/m²/s at your distance. How long must it run to reach 3 mol/m²/day?
3 ÷ (50 × 0.0036) = about 16.7 hours. That is past the 16-hour top the extension services give, so the light would need to come closer, or the target is too high for this light at this distance.
Why can a window spot's DLI not be worked out exactly from one phone reading?
Daylight changes through the day and with the weather. The DLI formula assumes a constant light. Thimijan and Heins say a single sunlight reading does not give a day's average, so any DLI from one window reading is an estimate at best.
(Go deeper) Why does the manual not judge a window spot against Iowa State's DLI categories?
Converted at 12 hours of daylight, the foot-candle scale's low band gives about 0.6 to 1.7 mol/m²/day, while Iowa State's low category starts at 3. The two scales appear to answer different questions (keeping a plant indoors, and growing plants under lights), and no source reconciles them, so the manual keeps them apart.
You want a grow light for a fern in a north room. The one you like says "full spectrum" and "45 W" on the box and has no PPFD chart. What do you do?
"Full spectrum" has no standard meaning, and watts measure the electricity the light draws, not the light at the fern. Neither tells you the PPFD at the distance you can hang it, so you have nothing to work out hours or a DLI from.
A PPFD chart at a stated distance is the number that sizes a light. Without one, a lux reading at the fronds turned into an estimate with the right factor gives you a range to set hours from. Either way, the fern's new fronds over the following weeks settle whether it is enough.
A reasonable alternative if a brighter window exists. Measure the new spot first, check the fern's band in Plants, one by one, and move it by stages, as Matching plants to light describes. The tradeoff is that a window's light changes through the year, and a light on a timer does not.

Checklist

Records your learning only; it is not a qualification.